myServer now has a driver to support the AHM 16 and 32 matrices.
Note that the driver may have to be modded by Allonis for the specifics of a given project (mono vs. stereo etc)
Installation:
AHM processors communicate over TCP/IP. All devices on the network must have compatible
IP addresses. Factory defaults for AHM-16 and AHM-32 are:
IP Address 192.168.1.91 Subnet Mask 255.255.255.0 Gateway 192.168.1.254
Download and install the AHM driver from myServer Software Updater.
Ensure that the AHM matrix is on the same subnet as myServer.
You can click "Discovery" button at the bottom of the Driver's Configuration page. This will navigate your network subnet to find a AHM on your network. If it is found, it will self configure. You can also manually add the matrix using the AddController command.
The first device should be setup with the Audio matrix IP address like:
When you have all of your devices configured, it should look like:
Note the first matrix the Logical and Real IDs are the same. For subsequent matrices, the Logical would be "17" and the Real ID would be "1" (if the first AHM was 16 outputs).
The AHM communicates on port 51325.